Differential scanning calorimeter DSC-600
Product classification: Differential scanning calorime
Differential scanning calorimetry, as a classical thermal analysis method, has been widely used in the research and development, process optimization, quality control and failure analysis of various materials and chemistry fields.
Order Hotline:+086-025-52702696
Consult
Instrument introduction:
Differential scanning calorimetry, as a classical thermal analysis method, has been widely used in the research and development, process optimization, quality control and failure analysis of various materials and chemistry fields. With DSC method, we can study the phase transformation of inorganic materials, melting of polymer materials, crystallization process, polymorphism of drugs, solid / liquid phase ratio of oil and other foods, etc.
Instrument purpose:
Measure the physical and chemical changes related to heat, such as glass transition temperature, melting point, melting temperature, crystallization and crystallization heat, phase transition reaction heat, thermal stability of products, curing / crosslinking, oxidation induction period, etc.
Main features:
1. The new fully enclosed metal furnace design structure greatly improves sensitivity, resolution and baseline stability.
2. It adopts imported alloy sensor, which is more corrosion-resistant, anti-oxidation and high sensitivity.
3. With Cortex-M3 core arm controller, the operation speed is faster and the temperature control is more accurate.
4. USB two-way communication is adopted to realize intelligent operation.
5. The 7-inch 24 bit color full-color LCD touch screen is used to display the status and data of the instrument in real time.
6. Intelligent software design, automatic drawing of the whole instrument, software can realize various data processing, such as calculation of enthalpy, glass transition temperature, oxidation induction period, melting point and crystallization of substances, etc.
技术参数:
1. DSC range: 0~±500mW
2. Temperature range: room temperature~600℃
3. heating rate: 0.1~80℃/min
4. DSC sensitivity: 0.01mW
6. Temperature repeatability: ±0.1℃
7. DSC Noise: 0.001mW
8. DSC Resolution: 0.001mW
9. DSC accuracy: 0.01mW
10. Temperature resolution: 0.1℃
11. Temperature control mode: temperature rise: program control can adjust parameters as required
Constant temperature: program controlled constant temperature time can be set at will
12. Curve scan: temperature rise scan
13. Atmosphere control: automatic switching of instrument
14. Gas flow:0-200mL/min
15. Gas pressure:0.2MPa
16. Display mode: 24 bit color 7 inch LCD touch screen display
17. Data interface: standard USB interface
18. Parameter standard: equipped with reference material, with one button calibration function, user can self calibrate temperature and enthalpy
19. Working power supply: AC 220V 50Hz or customized
20. Power:600W
Reference standards:
GB/T 19466.2 – 2004 / ISO 11357-2: 1999Part 2: Determination of glass transition temperature;
GB/T 19466.3 – 2004 / ISO 11357-3: 1999Part 3: Determination of melting and crystallization temperature and enthalpy;
GB /T 19466.6- 2009/ISO 11357-3 :1999 Part 6 Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) during oxidation induction period。
-
Differential scanning calorimet
Differential scanning calorimetry, as a classical thermal analysis method, has be... -
Differential scanning calorimet
Differential scanning calorimetry, as a classical thermal analysis method, has be... -
DSC-600BL Low temperature diffe
Differential scanning calorimetry (DSC), as a classical thermal analysis method o...
- Nanjing Huicheng Instrument Co., Ltd
- Service hotline:025-52702696
- After-sale service:025-52702696
- E-mail:njhcyq@163.com
- Company address: Building 3, runjing Technology Plaza, No.9, Tianhang West Road, Jiangning District, Nanjing